{"id":2993,"date":"2026-10-23T09:17:00","date_gmt":"2026-10-23T01:17:00","guid":{"rendered":"https:\/\/borrapumps.com\/blog\/centrifugal-pump-power-calculation\/"},"modified":"2026-10-23T09:17:00","modified_gmt":"2026-10-23T01:17:00","slug":"calculo-de-la-potencia-de-la-bomba-centrifuga","status":"publish","type":"post","link":"https:\/\/borrapumps.com\/es\/blog\/centrifugal-pump-power-calculation\/","title":{"rendered":"Calculo de la potencia de la bomba centr\u00edfuga: potencia hidr\u00e1ulica, potencia del eje y entrada del motor"},"content":{"rendered":"<p>A centrifugal pump power calculation starts with hydraulic power: liquid density multiplied by gravitational acceleration, flow, and differential head. Divide hydraulic power by pump efficiency to estimate shaft power, then account for motor and drive efficiency to estimate electrical input. Keep those power boundaries separate. The result applies to a defined operating point and stated liquid conditions; it is not automatically the motor rating, starting demand, or annual electricity consumption. Select equipment using the complete duty range and the manufacturer&#8217;s documented performance rather than one isolated formula.<\/p>\n<h2>Define what power you need to calculate<\/h2>\n<p>Hydraulic power is the useful rate of energy transferred to the liquid under the chosen definition of head. Shaft power is the mechanical power delivered to the pump shaft. Electrical input is the power drawn upstream of the motor, with the measurement boundary identified. If a variable-speed drive is included, its losses depend on whether the input boundary is at the drive supply or the motor terminals.<\/p>\n<p>A quotation can use terms such as absorbed power, brake power, input power, or rated power. Ask the supplier to define the term and unit rather than assuming that every number describes the same boundary. The motor nameplate rating commonly refers to rated mechanical output under specified conditions. It should not be casually compared with a site electrical-input reading as if they were identical quantities.<\/p>\n<p>The US Department of Energy&#8217;s <a href=\"https:\/\/www.energy.gov\/cmei\/ito\/pump-systems\" rel=\"noopener\" target=\"_blank\">pump systems resources<\/a> provide the system-efficiency context. A calculation is useful only when the flow, head, efficiency, operating condition, and power boundary refer to the same case.<\/p>\n<h2>Use consistent units in the hydraulic equation<\/h2>\n<p>In SI units, hydraulic power in watts is P = \u03c1gQH. Here \u03c1 is liquid density in kg\/m\u00b3, g is approximately 9.81 m\/s\u00b2, Q is flow in m\u00b3\/s, and H is differential head in metres. Divide by 1,000 for kilowatts. If flow is supplied in m\u00b3\/h, divide it by 3,600 before using that form of the equation.<\/p>\n<p>For ordinary water near a density of 1,000 kg\/m\u00b3, the same arithmetic can be written as hydraulic kW \u2248 Q in m\u00b3\/h \u00d7 H in m \u00f7 367. The convenient denominator is rounded and incorporates the assumed density and gravitational acceleration. It is not a universal formula for every liquid. Retain the full density-based expression when the liquid or temperature makes that assumption unsuitable.<\/p>\n<p>Avoid mixing head in feet with flow in cubic metres per hour or inserting litres per second into an equation expecting cubic metres per second. A worksheet should display units beside every input and retain the conversion steps. Plausible-looking numbers are particularly dangerous when an unnoticed unit error introduces a factor of 1,000 or 3,600.<\/p>\n<figure><img decoding=\"async\" alt=\"ISG Vertical Inline Booster Pump, Red Original in an illustrative equipment setting\" height=\"1024\" loading=\"lazy\" src=\"https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-007.webp\" width=\"1536\"\/><figcaption>ISG Vertical Inline Booster Pump, Red Original. Generated illustration based on the BORRAPUMP product original; it does not document a customer installation or establish model-specific performance.<\/figcaption><\/figure>\n<h2>Work through a bounded example<\/h2>\n<p>Assume an illustrative water duty of 36 m\u00b3\/h at 25 m differential head, with density taken as 1,000 kg\/m\u00b3. Convert flow to 0.010 m\u00b3\/s. Hydraulic power is then 1,000 \u00d7 9.81 \u00d7 0.010 \u00d7 25 = 2,452.5 W, or approximately 2.45 kW. These values are an arithmetic example and are not specifications for a BORRAPUMP model.<\/p>\n<p>If the pump efficiency at that duty were 70%, shaft power would be 2.45 \u00f7 0.70 \u2248 3.50 kW. If motor efficiency at the relevant load were 90%, electrical input at the motor boundary would be approximately 3.50 \u00f7 0.90 = 3.89 kW. With an illustrative drive efficiency of 97%, supply input upstream of that drive would be about 4.01 kW.<\/p>\n<p>Each efficiency in this example is assumed solely to demonstrate the calculation. An equipment selection needs the actual supplier data at the intended duty, speed, and load. Do not copy the example efficiencies into a procurement worksheet and describe them as verified performance. Rounding should also be appropriate to the uncertainty of the inputs rather than implying laboratory precision.<\/p>\n<h2>Obtain head from the system requirement<\/h2>\n<p>Use differential head required at the operating duty, not the height of the building alone or a pump&#8217;s catalog maximum head. The requirement can include elevation change, friction losses, and pressure differences between the defined system boundaries. The <a href=\"https:\/\/borrapumps.com\/blog\/pump-duty-point-calculation\/\">pump duty-point calculation guide<\/a> explains the information to assemble.<\/p>\n<p>For measurements across a pump, gauge locations, elevation differences, liquid density, and velocity-head differences can affect the conversion from pressure readings to differential head. Record the method and references. A discharge gauge reading alone does not generally establish the pump&#8217;s differential head when suction pressure is significant.<\/p>\n<p>The <a href=\"https:\/\/borrapumps.com\/product\/is-clean-water-centrifugal-pump\/\">IS clean-water centrifugal pump<\/a> is a route for requesting an offered model&#8217;s curve and absorbed-power data. A family description or motor size does not identify the efficiency or shaft power of every operating point. Ask for the actual impeller and speed represented by the quotation.<\/p>\n<h2>Use efficiency at the operating point<\/h2>\n<p>Pump efficiency changes with flow, speed, impeller configuration, and other operating conditions. A maximum efficiency shown in a brochure may occur at a different point from the intended duty. Use the appropriate curve and distinguish a measured value, supplier prediction, and preliminary assumption. The <a href=\"https:\/\/borrapumps.com\/blog\/how-to-read-centrifugal-pump-curve\/\">curve-reading guide<\/a> helps locate the required information.<\/p>\n<p>Motor and drive efficiencies also depend on their own operating conditions. A single nameplate or catalog efficiency may not describe every part-load case. When an energy estimate affects a purchasing decision, obtain suitable efficiency information for the expected operating profile and state the limitations. Do not multiply unrelated peak efficiencies and claim a guaranteed wire-to-water result.<\/p>\n<div style=\"overflow-x:auto\">\n<table>\n<thead>\n<tr>\n<th>Quantity<\/th>\n<th>Calculation boundary<\/th>\n<th>Information needed<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Hydraulic power<\/td>\n<td>Energy transferred to the liquid<\/td>\n<td>Density, flow and differential head<\/td>\n<\/tr>\n<tr>\n<td>Pump shaft power<\/td>\n<td>Mechanical power entering the pump<\/td>\n<td>Hydraulic power and duty-point pump efficiency<\/td>\n<\/tr>\n<tr>\n<td>Motor electrical input<\/td>\n<td>Electrical power entering the motor<\/td>\n<td>Shaft power and motor efficiency at the relevant load<\/td>\n<\/tr>\n<tr>\n<td>Drive supply input<\/td>\n<td>Electrical power entering the drive<\/td>\n<td>Motor demand and applicable drive losses<\/td>\n<\/tr>\n<tr>\n<td>Energy use<\/td>\n<td>Power integrated over operating time<\/td>\n<td>A realistic load and operating-time profile<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The table separates quantities that should not be interchanged. It does not provide a motor-selection margin or certify an efficiency. The supplier&#8217;s curve and the applicable equipment requirements remain necessary for selection.<\/p>\n<figure><img decoding=\"async\" alt=\"ISW Horizontal Inline Pump, Blue Original in an illustrative equipment setting\" height=\"1024\" loading=\"lazy\" src=\"https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-012.webp\" width=\"1536\"\/><figcaption>ISW Horizontal Inline Pump, Blue Original. Generated illustration based on the BORRAPUMP product original; it does not document a customer installation or establish model-specific performance.<\/figcaption><\/figure>\n<h2>Review power over the permitted operating range<\/h2>\n<p>One duty-point calculation can miss the highest shaft-power demand encountered in service. Check the absorbed-power curve across the intended range of flow and speed, including credible control combinations. The shape of the power curve varies with pump design; do not assume that every centrifugal pump has its highest demand at the same relative location.<\/p>\n<p>A system change can move the operating point. Opening a lower-resistance path, changing a valve position, adding a parallel pump, or changing a setpoint may alter both flow and power. The Hydraulic Institute&#8217;s discussion of <a href=\"https:\/\/www.pumps.org\/2022\/12\/07\/the-basics-of-npsh-pump-operating-regions\/\" rel=\"noopener\" target=\"_blank\">NPSH and operating regions<\/a> also matters because an electrically acceptable power value does not prove that the hydraulic operating point is acceptable.<\/p>\n<p>Motor selection must consider the complete application: permitted operating power, duty, environment, supply, starting method, equipment limits, and applicable requirements. Do not treat an arbitrary percentage added to the example shaft power as a complete selection rule. Ask the supplier and responsible electrical designer to confirm the offered motor against the actual range.<\/p>\n<h2>Keep starting demand separate from running power<\/h2>\n<p>A motor can demand substantially different electrical conditions while accelerating from those seen at steady operation. Running kW alone therefore cannot size a generator, feeder, protective device, or starting system. Obtain the relevant starting information and assess it using the actual supply and control arrangement.<\/p>\n<p>The <a href=\"https:\/\/borrapumps.com\/blog\/pump-motor-starting-current\/\">pump motor starting-current guide<\/a> addresses that separate question. For a generator supply, review the transient response and voltage recovery as well as the steady load. A motor that is adequate mechanically can still fail to accelerate normally when the supply or starting arrangement is unsuitable.<\/p>\n<p>Electrical measurements and changes require competent personnel and suitable procedures. Avoid estimating three-phase input power from current alone without the relevant voltage, power factor, efficiency boundary, and measurement conditions. Where actual energy use matters, an appropriately applied power measurement provides stronger evidence than a simplified current-only approximation.<\/p>\n<h2>Estimate electricity use from the operating profile<\/h2>\n<p>Electrical energy in kWh is power in kW multiplied by time in hours for a constant-power interval. For changing operation, calculate the intervals separately or integrate measured power over time. A pump drawing 4 kW for 6 hours uses 24 kWh during that interval; the number says nothing about the remaining hours without an operating schedule.<\/p>\n<p>Include staged pumps, variable demand, standby periods, and auxiliary loads where they fall within the stated measurement boundary. Keep the tariff and operating-hour assumptions visible when estimating cost. Separate a theoretical annual estimate from measured consumption, and avoid promising savings based solely on the difference between two motor nameplate ratings.<\/p>\n<h2>Further learning<\/h2>\n<p>NPTEL&#8217;s \u201cMod-01 Lec-15 Characteristics of a Centrifugal Pump\u201d explains the relationship between pump performance and operating conditions. Use the lecture to support curve interpretation, then use model-specific supplier data for the actual power worksheet and equipment selection.<\/p>\n<div style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"><iframe allowfullscreen=\"\" loading=\"lazy\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/p54HAatQOcA\" style=\"position:absolute;inset:0;width:100%;height:100%;border:0\" title=\"Mod-01 Lec-15 Characteristics of a Centrifugal Pump - NPTEL\"><\/iframe><\/div>\n<h2>Frequently asked questions<\/h2>\n<h3>Is hydraulic power the motor rating?<\/h3>\n<p>No. Hydraulic power describes energy transferred to the liquid. Shaft power includes pump losses, and electrical input includes the losses within the stated motor and drive boundary. The selected motor must suit the complete application.<\/p>\n<h3>Can I use the pump&#8217;s maximum efficiency?<\/h3>\n<p>Only if it applies to the operating point being calculated. Otherwise use the appropriate duty-point efficiency or label the preliminary assumption clearly and replace it with supplier data before selection.<\/p>\n<h3>Does a higher motor rating mean higher electricity use?<\/h3>\n<p>Not by itself. Actual input depends on the load, efficiencies, operating conditions, controls, and time. Nameplate ratings alone do not establish measured consumption or annual running cost.<\/p>\n<h3>Can this calculation size a generator?<\/h3>\n<p>It can contribute steady-load information, but it does not resolve motor starting, transient voltage response, other loads, or control requirements. Those need a separate assessment for the actual generator and starting arrangement.<\/p>\n<h3>What should a supplier provide for verification?<\/h3>\n<p>Request the duty-specific curve, absorbed-power curve, efficiency information, liquid and speed assumptions, offered motor details, and the approved operating range. Keep those documents with the final calculation.<\/p>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Is hydraulic power the motor rating?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. Hydraulic power describes energy transferred to the liquid. Shaft power includes pump losses, and electrical input includes the losses within the stated motor and drive boundary. The selected motor must suit the complete application.\"}}, {\"@type\": \"Question\", \"name\": \"Can I use the pump's maximum efficiency?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Only if it applies to the operating point being calculated. Otherwise use the appropriate duty-point efficiency or label the preliminary assumption clearly and replace it with supplier data before selection.\"}}, {\"@type\": \"Question\", \"name\": \"Does a higher motor rating mean higher electricity use?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Not by itself. Actual input depends on the load, efficiencies, operating conditions, controls, and time. Nameplate ratings alone do not establish measured consumption or annual running cost.\"}}, {\"@type\": \"Question\", \"name\": \"Can this calculation size a generator?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"It can contribute steady-load information, but it does not resolve motor starting, transient voltage response, other loads, or control requirements. Those need a separate assessment for the actual generator and starting arrangement.\"}}, {\"@type\": \"Question\", \"name\": \"What should a supplier provide for verification?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Request the duty-specific curve, absorbed-power curve, efficiency information, liquid and speed assumptions, offered motor details, and the approved operating range. Keep those documents with the final calculation.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Calcula la potencia hidr\u00e1ulica de la bomba centr\u00edfuga, la potencia del eje y la potencia el\u00e9ctrica con unidades SI coherentes, eficiencia en puntos de carga y un ejemplo pr\u00e1ctico.<\/p>","protected":false},"author":6,"featured_media":2735,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[95],"tags":[],"class_list":["post-2993","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pump"],"_links":{"self":[{"href":"https:\/\/borrapumps.com\/es\/wp-json\/wp\/v2\/posts\/2993","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/borrapumps.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/borrapumps.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/borrapumps.com\/es\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/borrapumps.com\/es\/wp-json\/wp\/v2\/comments?post=2993"}],"version-history":[{"count":1,"href":"https:\/\/borrapumps.com\/es\/wp-json\/wp\/v2\/posts\/2993\/revisions"}],"predecessor-version":[{"id":3021,"href":"https:\/\/borrapumps.com\/es\/wp-json\/wp\/v2\/posts\/2993\/revisions\/3021"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/borrapumps.com\/es\/wp-json\/wp\/v2\/media\/2735"}],"wp:attachment":[{"href":"https:\/\/borrapumps.com\/es\/wp-json\/wp\/v2\/media?parent=2993"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/borrapumps.com\/es\/wp-json\/wp\/v2\/categories?post=2993"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/borrapumps.com\/es\/wp-json\/wp\/v2\/tags?post=2993"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}