{"id":1146,"date":"2026-08-08T09:00:00","date_gmt":"2026-08-08T01:00:00","guid":{"rendered":"https:\/\/borrapumps.com\/blog\/electric-submersible-pump-diagram\/"},"modified":"2026-08-08T09:00:00","modified_gmt":"2026-08-08T01:00:00","slug":"electric-submersible-pump-diagram","status":"publish","type":"post","link":"https:\/\/borrapumps.com\/ru\/blog\/electric-submersible-pump-diagram\/","title":{"rendered":"What Should an Electric Submersible Pump Diagram Show for Project Review?"},"content":{"rendered":"<div class=\"b2b-article\">\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>An electric submersible pump diagram should make the liquid path, discharge route, cable and control relationship, source condition, and service access visible before a project team treats any equipment as a fit.<\/strong> It is a review aid, not a universal wiring drawing or a substitute for the actual product instructions.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"BORRAPUMP WQ submersible sewage pump used as a project-review reference for a submersible pump layout\" src=\"https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/05\/WQ-Submersible-Sewage-Pump-For-Dewate.webp\" \/><\/figure>\n<nav class=\"b2b-toc\" style=\"background:#f5f8fa;padding:16px 20px;border-radius:8px;margin:0 0 24px\">\n<h2 id=\"contents\" style=\"margin:42px 0 14px;scroll-margin-top:96px\">Contents<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"#part-1-read-the-diagram-as-a-system-record\">Part 1. Read the Diagram as a System Record<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-2-mark-the-liquid-and-discharge-path\">Part 2. Mark the Liquid and Discharge Path<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-3-separate-cable-and-control-review-from-pump-selection\">Part 3. Separate Cable and Control Review From Pump Selection<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-4-add-source-conditions-and-service-access\">Part 4. Add Source Conditions and Service Access<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-5-turn-the-diagram-into-a-controlled-inquiry\">Part 5. Turn the Diagram Into a Controlled Inquiry<\/a><\/li>\n<li style=\"margin:0 0 8px\"><a href=\"#part-6-keep-the-diagram-within-its-fit-boundary\">Part 6. Keep the Diagram Within Its Fit Boundary<\/a><\/li>\n<\/ul>\n<\/nav>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-1-read-the-diagram-as-a-system-record\">Part 1. Read the Diagram as a System Record<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">A useful layout begins with the job, not a product silhouette. It should show where liquid enters the system, where it leaves, what sits between those points, and who must review the electrical and service conditions. The <a href=\"https:\/\/borrapumps.com\/ru\/%d0%b1%d0%bb%d0%be%d0%b3\/sewage-pump\/\">BORRAPUMP Sewage Pump guide<\/a> provides the cluster context; the diagram keeps the project-specific route visible.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Diagram zone<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">What to identify<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">\u041f\u043e\u0447\u0435\u043c\u0443 \u044d\u0442\u043e \u0432\u0430\u0436\u043d\u043e<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Source<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Pit, tank, sump, or other intake condition<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">The pump cannot be selected apart from the source<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Pump location<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Intended submerged position and access concept<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Supports installation and service review<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Discharge<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Outlet, line route, fittings, and destination<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Defines the liquid path<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Electrical<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable route and responsible control point<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Separates electrical review from assumptions<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Service<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Lifting, inspection, and access notes<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Avoids an unserviceable layout<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-2-mark-the-liquid-and-discharge-path\">Part 2. Mark the Liquid and Discharge Path<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">The flow path should identify the intake condition, pump discharge connection, line route, elevation changes, fittings, and receiving point. A diagram does not need to invent flow or head values to be useful; it needs to show where the project must supply those values. The <a href=\"https:\/\/borrapumps.com\/ru\/%d0%b1%d0%bb%d0%be%d0%b3\/sewage-pump-solids-handling\/\">Sewage Pump Solids Handling<\/a> article helps keep liquid and solids description separate from a generic product label.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Mark on the layout<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Project review question<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Do not assume<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Source level and condition<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Is the intake environment described?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Every pit has the same duty<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Discharge route<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Are length, elevation, and fittings recorded?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">A straight line is the real route<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Destination<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Can the receiving point accept the liquid?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Discharge is unrestricted<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Liquid note<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Are solids, temperature, or chemistry known?<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">A sewage label proves compatibility<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<blockquote>\n<p style=\"margin:0 0 16px;line-height:1.7\"><strong>Important:<\/strong> A layout should record unknowns instead of hiding them. <a href=\"https:\/\/www.pumps.org\/\" target=\"_blank\" rel=\"noopener\">Hydraulic Institute<\/a> selection context starts with stated system conditions; confirm the exact model and project documents before installation.<\/p>\n<\/blockquote>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-3-separate-cable-and-control-review-from-pump-selection\">Part 3. Separate Cable and Control Review From Pump Selection<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">An electric submersible layout can show the cable route and a control relationship, but it should never be read as a universal wiring instruction. Actual supply, protection, control logic, cable specification, and installation requirements must come from the specific product documentation and the responsible electrical review.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"BORRAPUMP ZW non-clogging self-priming sewage pump shown as a contrasting route when a submersible layout does not fit the documented access or intake conditions\" src=\"https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/05\/ZW-Non-clogging-Self-priming-Sewage-Pump.webp\" \/><\/figure>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Electrical label<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Purpose in the diagram<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Required confirmation<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Cable path<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Shows the physical route and protection concern<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Actual cable and installation requirements<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Control point<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Shows where start\/stop responsibility is reviewed<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Product-specific controls and site procedure<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Supply reference<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Flags an electrical dependency<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Available supply and protective arrangement<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Alarm or level note<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Flags a project interface<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Actual control design and responsibility<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">See <a href=\"https:\/\/borrapumps.com\/ru\/%d0%b1%d0%bb%d0%be%d0%b3\/submersible-vs-self-priming-drainage-pump\/\">Submersible vs Self-Priming Drainage Pump<\/a> when access or intake conditions point to a different equipment family. Do not change pump families only because a generic diagram appears simpler.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-4-add-source-conditions-and-service-access\">Part 4. Add Source Conditions and Service Access<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">The source condition affects how the diagram is read. Mark access, lifting or removal concept, visibility, debris or solids notes, and the parts of the route that must remain accessible. A compact diagram can still make these review points explicit without pretending to be a construction drawing.<\/p>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Review item<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Include on the record<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Escalate when<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Access<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Working space and removal concept<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Service cannot be performed safely<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Source condition<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Liquid level, debris, and known constraints<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Duty is not documented<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Line service<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Isolation, check, or service notes where applicable<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">The line cannot be reviewed or maintained<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Responsibility<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Installer, electrical reviewer, and operator roles<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Ownership is unclear<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">The separate <a href=\"https:\/\/borrapumps.com\/ru\/%d0%b1%d0%bb%d0%be%d0%b3\/drainage-pump-installation-checklist\/\">Drainage Pump Installation<\/a> guide offers supporting installation questions. It does not approve an actual site layout.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-5-turn-the-diagram-into-a-controlled-inquiry\">Part 5. Turn the Diagram Into a Controlled Inquiry<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Once the diagram names the source, discharge route, liquid, access, and electrical interfaces, it can become an RFQ attachment. That gives a supplier the context needed to discuss a WQ submersible path or a self-priming alternative without replacing project data with a generic diagram.<\/p>\n<figure style=\"margin:26px 0;text-align:center\"><img decoding=\"async\" style=\"max-width:640px;width:100%;height:auto;display:block;margin:0 auto;border-radius:8px\" alt=\"BORRAPUMP SP self-priming dirt drain pump used to show a separate equipment family for documented dirty-drain conditions\" src=\"https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/05\/SP-Jam-less-Self-priming-Dirt-Drain-Pump.webp\" \/><\/figure>\n<table style=\"width:100%;border-collapse:collapse\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Documented need<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">BORRAPUMP route<\/th>\n<th style=\"border:1px solid #d9e1e8;padding:9px 12px;background:#f5f8fa;text-align:left\">Send with quote<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Submerged sewage or drainage duty<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\"><a href=\"https:\/\/borrapumps.com\/ru\/product\/wq-submersible-sewage-pump\/\">WQ Submersible Sewage Pump<\/a><\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Source layout, liquid, flow\/head basis, discharge route, power, access, destination<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Non-clogging self-priming review<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\"><a href=\"https:\/\/borrapumps.com\/ru\/product\/zw-non-clogging-self-priming-sewage-pump\/\">\u0421\u0430\u043c\u043e\u0437\u0430\u043f\u043e\u043b\u043d\u044f\u044e\u0449\u0438\u0439\u0441\u044f \u043d\u0430\u0441\u043e\u0441 \u0434\u043b\u044f \u0441\u0442\u043e\u0447\u043d\u044b\u0445 \u0432\u043e\u0434 \u0431\u0435\u0437 \u0437\u0430\u0441\u043e\u0440\u0435\u043d\u0438\u044f ZW<\/a><\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Intake arrangement, liquid and solids description, route, duty basis, power, destination<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Dirty-drain route review<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">SP discussion after duty is documented<\/td>\n<td style=\"border:1px solid #d9e1e8;padding:9px 12px\">Debris, route, driver preference, access, destination<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"margin:0 0 16px;line-height:1.7\">Share the marked-up record with <a href=\"https:\/\/borrapumps.com\/ru\/contact-us\/\">\u0411\u041e\u0420\u0420\u0410\u041f\u0410\u041c\u041f<\/a> for a controlled discussion. A generic electric submersible pump diagram is not evidence that a particular model has been selected.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"part-6-keep-the-diagram-within-its-fit-boundary\">Part 6. Keep the Diagram Within Its Fit Boundary<\/h2>\n<p style=\"margin:0 0 16px;line-height:1.7\">Fits:<\/p>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Reading the relationship between source, pump, discharge, cable, controls, and access.<\/li>\n<li style=\"margin:0 0 8px\">Identifying the information that must accompany a project review or inquiry.<\/li>\n<\/ul>\n<p style=\"margin:0 0 16px;line-height:1.7\">Does not fit:<\/p>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\">Giving wiring, voltage, cable, protection, or performance instructions.<\/li>\n<li style=\"margin:0 0 8px\">Approving a pit, wet-well, electrical installation, or solids capability.<\/li>\n<li style=\"margin:0 0 8px\">Replacing the exact product manual, drawing, or responsible engineering review.<\/li>\n<\/ul>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"faq\">\u0427\u0430\u0441\u0442\u043e \u0437\u0430\u0434\u0430\u0432\u0430\u0435\u043c\u044b\u0435 \u0432\u043e\u043f\u0440\u043e\u0441\u044b<\/h2>\n<h3 style=\"margin:28px 0 12px\">What does an electric submersible pump diagram show?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">It should show the high-level relationship between the source, pump, discharge route, cable\/control interfaces, destination, and service access. The exact product documentation supplies model-specific details.<\/p>\n<h3 style=\"margin:28px 0 12px\">Does the diagram show the correct wiring for every pump?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No. Wiring, protection, cable details, and controls depend on the actual product and site. Use responsible electrical review and current product documentation.<\/p>\n<h3 style=\"margin:28px 0 12px\">What flow-path information should be marked?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Mark the source, discharge connection, route, elevation changes, fittings, receiving point, and liquid condition. Record unknown inputs instead of assuming them.<\/p>\n<h3 style=\"margin:28px 0 12px\">Why does the pit or source condition matter?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">It affects access, liquid conditions, debris exposure, service needs, and the suitability of the proposed pump route. A pump cannot be reviewed apart from the source.<\/p>\n<h3 style=\"margin:28px 0 12px\">What belongs in a submersible-pump inquiry?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">Send a marked-up layout, liquid description, flow\/head basis, discharge route, power information, access constraints, documents required, quantity, and destination.<\/p>\n<h3 style=\"margin:28px 0 12px\">Can a generic diagram approve installation?<\/h3>\n<p style=\"margin:0 0 16px;line-height:1.7\">No. It is a project-review aid only. The actual installation requires site-approved documents, responsible reviewers, and the exact product instructions.<\/p>\n<h2 style=\"margin:42px 0 14px;scroll-margin-top:96px\" id=\"references\">References<\/h2>\n<ul style=\"margin:0 0 18px 1.2em;line-height:1.7\">\n<li style=\"margin:0 0 8px\"><a href=\"https:\/\/www.pumps.org\/\" target=\"_blank\" rel=\"noopener\">Hydraulic Institute resources<\/a> for general pump-and-system selection context used when reviewing a project layout.<\/li>\n<\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>An electric submersible pump diagram should make the liquid path, discharge route, cable and control relationship, source condition, and service access visible before a project team treats any equipment as a fit. It is a review aid, not a universal wiring drawing or a substitute for the actual product instructions. Contents Part 1. Read the [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":178,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[31],"tags":[],"class_list":["post-1146","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-sewage-pump"],"_links":{"self":[{"href":"https:\/\/borrapumps.com\/ru\/wp-json\/wp\/v2\/posts\/1146","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/borrapumps.com\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/borrapumps.com\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/borrapumps.com\/ru\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/borrapumps.com\/ru\/wp-json\/wp\/v2\/comments?post=1146"}],"version-history":[{"count":0,"href":"https:\/\/borrapumps.com\/ru\/wp-json\/wp\/v2\/posts\/1146\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/borrapumps.com\/ru\/wp-json\/wp\/v2\/media\/178"}],"wp:attachment":[{"href":"https:\/\/borrapumps.com\/ru\/wp-json\/wp\/v2\/media?parent=1146"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/borrapumps.com\/ru\/wp-json\/wp\/v2\/categories?post=1146"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/borrapumps.com\/ru\/wp-json\/wp\/v2\/tags?post=1146"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}