{"id":3209,"date":"2026-11-21T13:38:00","date_gmt":"2026-11-21T05:38:00","guid":{"rendered":"https:\/\/borrapumps.com\/blog\/jockey-pump-not-starting\/"},"modified":"2026-11-21T13:38:00","modified_gmt":"2026-11-21T05:38:00","slug":"jockey-pump-not-starting","status":"publish","type":"post","link":"https:\/\/borrapumps.com\/th\/blog\/jockey-pump-not-starting\/","title":{"rendered":"\u0e1b\u0e31\u0e4a\u0e21\u0e08\u0e47\u0e2d\u0e01\u0e01\u0e35\u0e49\u0e44\u0e21\u0e48\u0e40\u0e23\u0e34\u0e48\u0e21\u0e17\u0e33\u0e07\u0e32\u0e19: \u0e41\u0e22\u0e01\u0e04\u0e27\u0e32\u0e21\u0e15\u0e49\u0e2d\u0e07\u0e01\u0e32\u0e23\u0e41\u0e23\u0e07\u0e14\u0e31\u0e19\u0e2d\u0e2d\u0e01\u0e08\u0e32\u0e01\u0e04\u0e27\u0e32\u0e21\u0e25\u0e49\u0e21\u0e40\u0e2b\u0e25\u0e27\u0e02\u0e2d\u0e07\u0e21\u0e2d\u0e40\u0e15\u0e2d\u0e23\u0e4c"},"content":{"rendered":"<p>When a jockey pump is not starting, first establish whether the controller actually has a valid automatic start demand. Compare its pressure reading with an independent gauge, check the operating mode and alarms from the outside, and record whether a start command appears. If a command exists but the motor remains stopped, the investigation moves toward the starter, supply, protection and motor circuit. If there is no command despite verified low pressure, investigate sensing and the approved control sequence. Do not bridge terminals, bypass protection or alter main fire-pump settings to force a result. Fire-protection availability must be managed throughout the investigation.<\/p>\n<p>This guide organizes evidence for a missing start and qualified service work. The separate <a href=\"https:\/\/borrapumps.com\/blog\/jockey-pump-testing-pressure-maintenance-checks\/\">jockey pump testing guide<\/a> covers broader pressure-maintenance checks. Use the specific failure record here to decide which part of that test sequence needs attention.<\/p>\n<h2>Protect the fire-protection service first<\/h2>\n<p>A jockey pump maintains pressure in the associated system; it is not a substitute for the main fire pump during a fire demand. Report a failure through the site&#8217;s fire-protection management process. The responsible party must decide whether an impairment procedure, notifications or temporary arrangements are necessary under the applicable requirements.<\/p>\n<p>Do not disable the main pump to make a jockey test easier. Pressure changes during investigation may start other equipment automatically. Agree the test boundary, communication method and stop conditions before manipulating a test connection. Coordinate with the facility operator and qualified fire-protection contractor rather than treating the equipment as an ordinary domestic booster.<\/p>\n<h2>Record exactly what does not start<\/h2>\n<p>An unlit screen, an illuminated controller with no start command, a contactor that operates without motor rotation, and a rotating motor that delivers no water are different symptoms. Write down what can actually be observed. Avoid a broad entry such as \u201cpump dead\u201d when the controller is powered and showing a pressure value.<\/p>\n<p>Capture the time, system pressure, indicated operating mode, active alarms and recent event history. Note whether the fault followed electrical maintenance, a pressure-sensor replacement, hydraulic work or a long power interruption. Record the last known successful automatic start, not merely the date someone heard the motor run.<\/p>\n<p>The <a href=\"https:\/\/borrapumps.com\/blog\/jockey-pump-controller-guide\/\">jockey pump controller guide<\/a> explains the controller&#8217;s role. For this investigation, its display and event log are evidence sources; they do not replace a verified understanding of the actual circuit and approved settings.<\/p>\n<figure><img decoding=\"async\" alt=\"EDJ Integrated Fire Pump Set in an illustrative setting\" class=\"wp-image-2734\" height=\"1024\" loading=\"lazy\" src=\"https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-001.webp\" width=\"1536\" srcset=\"https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-001.webp 1536w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-001-300x200.webp 300w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-001-1024x683.webp 1024w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-001-768x512.webp 768w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-001-18x12.webp 18w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-001-600x400.webp 600w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><figcaption>EDJ Integrated Fire Pump Set. Product-based illustration, not a customer installation or evidence of the internal components, accessories or connections discussed in this guide.<\/figcaption><\/figure>\n<h2>Confirm that an automatic start is expected<\/h2>\n<p>Find the approved cut-in setting and the specific controller&#8217;s start sequence. Compare them with verified system pressure. If pressure has not fallen to the applicable start condition, a stopped jockey pump may be behaving correctly. Do not lower system pressure casually just to see what happens.<\/p>\n<p>Pressure values entered into monitoring software may be descriptive records rather than active control settings. Confirm which device actually decides to start the jockey pump. An adjacent main-pump controller can display related information without controlling the jockey start threshold.<\/p>\n<p>Review the approved <a href=\"https:\/\/borrapumps.com\/blog\/jockey-pump-pressure-settings\/\">jockey pressure settings<\/a> and project records together. Do not borrow another installation&#8217;s pressure difference. The required relationship must account for the actual system and its applicable approval basis.<\/p>\n<h2>Compare pressure readings at understood locations<\/h2>\n<p>Use an independent gauge with a suitable range and known condition. Record where it connects, whether an isolation valve is open in the approved configuration, and whether elevation or intermediate piping explains a difference. A gauge downstream of a closed valve may not represent the pressure at the controller sensing connection.<\/p>\n<p>If the display shows normal pressure while a valid reference shows pressure below the expected start condition, investigate the sensing path and signal chain. An isolated sensing line, obstruction, incorrect scaling or damaged component can produce misleading information. Have the qualified contractor determine the appropriate test without opening a pressurized fitting.<\/p>\n<p>Do not assume the pressure switch has failed simply because the motor is stopped. Preserve the original settings and instrument identification. A replacement without a recorded as-found condition makes it harder to establish whether the true fault was measurement, configuration or wiring.<\/p>\n<h2>Use the start command to divide the investigation<\/h2>\n<div style=\"overflow-x:auto\">\n<table>\n<thead>\n<tr>\n<th>Evidence observed<\/th>\n<th>Likely investigation branch<\/th>\n<th>Record before intervention<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>No visible controller power indication<\/td>\n<td>Supply and controller power path<\/td>\n<td>Supply status, external switch indication and event timing<\/td>\n<\/tr>\n<tr>\n<td>Pressure above approved cut-in<\/td>\n<td>No automatic demand may be present<\/td>\n<td>Verified pressure and active setting<\/td>\n<\/tr>\n<tr>\n<td>Low pressure, no start command<\/td>\n<td>Mode, sensing and control sequence<\/td>\n<td>Gauge comparison, mode, alarms and timer status<\/td>\n<\/tr>\n<tr>\n<td>Start command present, motor stationary<\/td>\n<td>Starter, protection, supply or motor<\/td>\n<td>Command time, protective indication and qualified test results<\/td>\n<\/tr>\n<tr>\n<td>Motor rotates, pressure does not recover<\/td>\n<td>Hydraulic delivery problem<\/td>\n<td>Rotation evidence, pressure trend and valve configuration<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The table organizes observations; it does not establish a fault from a single indicator. A display may lag an event, and some controllers expose only a limited set of status information.<\/p>\n<h2>Check operating mode and sequence information<\/h2>\n<p>Read the mode shown on the controller and compare it with the approved normal operating state. A selector physically pointing toward a label is not enough if the display, remote signal or event record reports something different. Record any discrepancy for the service technician.<\/p>\n<p>Some installations include timers or interlocks. Their purpose and implementation must be established from the specific documentation. A start delay is different from a minimum-run timer that operates after starting. Do not assume that a timer whose name contains \u201crun\u201d explains a failure to issue a start command.<\/p>\n<p>A temporary manual test, where permitted, can help a contractor distinguish automatic-command problems from downstream motor-circuit problems. It must follow the actual controller procedure and site authorization. Successful manual operation does not prove that automatic pressure maintenance has been restored.<\/p>\n<figure><img decoding=\"async\" alt=\"XBC-W End Suction Diesel Engine Fire Pump in an illustrative setting\" class=\"wp-image-2826\" height=\"1024\" loading=\"lazy\" src=\"https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-015.webp\" width=\"1536\" srcset=\"https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-015.webp 1536w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-015-300x200.webp 300w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-015-1024x683.webp 1024w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-015-768x512.webp 768w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-015-18x12.webp 18w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-015-600x400.webp 600w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><figcaption>XBC-W End Suction Diesel Engine Fire Pump. Product-based illustration, not a customer installation or evidence of the internal components, accessories or connections discussed in this guide.<\/figcaption><\/figure>\n<h2>Investigate electrical faults without defeating protection<\/h2>\n<p>An overload or other protective indication is evidence of a condition to investigate. Repeated resetting can conceal the initial event and may expose equipment to further damage. Record the protection type, indication and time, then have qualified personnel identify the cause before restoring operation under the approved procedure.<\/p>\n<p>Electrical measurements inside a controller require the appropriate competence and safe-work arrangements. This article does not provide live-terminal testing instructions. The <a href=\"https:\/\/www.hse.gov.uk\/pubns\/indg261.pdf\" rel=\"noopener\" target=\"_blank\">HSE pressure systems guide<\/a> explains stored-pressure hazards and the need for safe maintenance arrangements. The specific installation still needs its own safe procedure and jurisdictional assessment.<\/p>\n<p>Do not copy terminal-bridging advice from an unrelated controller manual. Terminal functions, supply characteristics and protective circuits vary. A jumper that appears in one manufacturer&#8217;s troubleshooting chart may be inappropriate or dangerous on a different assembly.<\/p>\n<h2>Keep hydraulic delivery faults in their own branch<\/h2>\n<p>If the motor is actually running, the original description \u201cnot starting\u201d needs correction. Establish whether the observed movement belongs to the jockey motor and whether the pump develops the expected pressure. An operating light alone may report a command rather than confirmed rotation or flow.<\/p>\n<p>A qualified inspection can then review the approved valve configuration, liquid availability, pump priming where applicable and hydraulic restrictions. Avoid holding a running pump in an unverified condition while searching for the problem. Follow the equipment&#8217;s permitted operating limits and stop criteria.<\/p>\n<p>The pictured <a href=\"https:\/\/borrapumps.com\/product\/cdlf-vertical-multistage-jockey-pump\/\">CDL(F) vertical multistage jockey pump<\/a> is a real product reference. Its appearance does not prove the controller type, pressure setting, protection options or package approvals for a particular project. Match the nameplate and supplied documents before ordering replacement parts.<\/p>\n<h2>Plan a witnessed restoration test<\/h2>\n<p>State the repaired mechanism and the expected evidence before restarting. If a sensing problem was corrected, verify the pressure indication and automatic start together. If a motor-circuit fault was repaired, verify both authorized starting and subsequent normal pressure maintenance. A successful reset is not a complete acceptance test.<\/p>\n<p>Under the approved test procedure, observe the automatic start, pressure recovery, applicable stop sequence and return to normal mode. Record relevant alarms and ensure test connections and valves return to their required positions. Do not use a forced output as proof of automatic operation.<\/p>\n<p>The <a href=\"https:\/\/docinfofiles.nfpa.org\/files\/AboutTheCodes\/20\/20_A2024_FIM_AAA_SD_Agenda_10_23.pdf\" rel=\"noopener\" target=\"_blank\">NFPA 20 development meeting material<\/a> provides background on fire-pump and pressure-maintenance topics. It is development material, not the adopted standard for every installation. Obtain the applicable adopted edition and project approvals for actual acceptance requirements.<\/p>\n<h2>Prepare a useful service request<\/h2>\n<p>Provide pump and controller identification, photographs of external labels, the approved schematic and settings, pressure readings with locations, the observed mode, event logs and protection indications. Describe whether the motor never turned, turned only in a permitted manual test, or ran without recovering pressure.<\/p>\n<p>Include recent work and any temporary configuration changes. A concise timeline is more useful than a list of parts already replaced. Ask the contractor to return an as-found diagnosis, corrective action, final automatic-test record and confirmation that normal service arrangements were restored.<\/p>\n<p>The neutral educational video below explains pressure and flow as background. It does not demonstrate fire-controller troubleshooting or replace the project-specific witnessed test.<\/p>\n<div style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"><iframe allowfullscreen=\"\" loading=\"lazy\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/m3i_5xP9PYU\" style=\"position:absolute;inset:0;width:100%;height:100%;border:0\" title=\"Do Pumps Create Pressure or Flow? - Practical Engineering\"><\/iframe><\/div>\n<h2>Frequently asked questions<\/h2>\n<h3>Should the jockey pump run whenever the main pump is stopped?<\/h3>\n<p>No. Its automatic operation depends on the approved pressure-maintenance sequence and actual system conditions. A stopped jockey pump with adequate pressure may be normal. Establish a valid start demand before diagnosing a failure.<\/p>\n<h3>Can a closed sensing valve prevent an automatic start?<\/h3>\n<p>An incorrect sensing arrangement can prevent the controller from receiving representative pressure information. Verify the actual installation and approved valve positions with the responsible contractor; do not open pressurized fittings to experiment.<\/p>\n<h3>Is a successful manual start enough to close the fault?<\/h3>\n<p>No. It can show that part of the motor circuit operates, but automatic sensing, mode and sequence may still be faulty. Restoration needs the applicable automatic test and a documented return to normal operation.<\/p>\n<h3>Can I raise the main fire-pump start setting to help?<\/h3>\n<p>Do not change the main fire-pump sequence to compensate for a jockey fault. Preserve the approved settings and have the responsible fire-protection specialist assess the failed pressure-maintenance function and service implications.<\/p>\n<h3>What information helps avoid an unnecessary pump replacement?<\/h3>\n<p>A clear start-command record, independent pressure comparison, controller mode, protection indication and qualified electrical diagnosis help separate pump, motor, sensing and control faults. Replacing the hydraulic pump cannot correct an absent start command.<\/p>\n<p><script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Should the jockey pump run whenever the main pump is stopped?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. Its automatic operation depends on the approved pressure-maintenance sequence and actual system conditions. A stopped jockey pump with adequate pressure may be normal. Establish a valid start demand before diagnosing a failure.\"}}, {\"@type\": \"Question\", \"name\": \"Can a closed sensing valve prevent an automatic start?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"An incorrect sensing arrangement can prevent the controller from receiving representative pressure information. Verify the actual installation and approved valve positions with the responsible contractor; do not open pressurized fittings to experiment.\"}}, {\"@type\": \"Question\", \"name\": \"Is a successful manual start enough to close the fault?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. It can show that part of the motor circuit operates, but automatic sensing, mode and sequence may still be faulty. Restoration needs the applicable automatic test and a documented return to normal operation.\"}}, {\"@type\": \"Question\", \"name\": \"Can I raise the main fire-pump start setting to help?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Do not change the main fire-pump sequence to compensate for a jockey fault. Preserve the approved settings and have the responsible fire-protection specialist assess the failed pressure-maintenance function and service implications.\"}}, {\"@type\": \"Question\", \"name\": \"What information helps avoid an unnecessary pump replacement?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A clear start-command record, independent pressure comparison, controller mode, protection indication and qualified electrical diagnosis help separate pump, motor, sensing and control faults. Replacing the hydraulic pump cannot correct an absent start command.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u0e27\u0e34\u0e19\u0e34\u0e08\u0e09\u0e31\u0e22\u0e1b\u0e31\u0e4a\u0e21\u0e08\u0e47\u0e2d\u0e01\u0e01\u0e35\u0e49\u0e17\u0e35\u0e48\u0e44\u0e21\u0e48\u0e40\u0e23\u0e34\u0e48\u0e21\u0e17\u0e33\u0e07\u0e32\u0e19\u0e42\u0e14\u0e22\u0e01\u0e32\u0e23\u0e41\u0e22\u0e01\u0e04\u0e27\u0e32\u0e21\u0e15\u0e49\u0e2d\u0e07\u0e01\u0e32\u0e23\u0e41\u0e23\u0e07\u0e14\u0e31\u0e19, \u0e01\u0e32\u0e23\u0e15\u0e23\u0e27\u0e08\u0e08\u0e31\u0e1a, \u0e04\u0e33\u0e2a\u0e31\u0e48\u0e07\u0e04\u0e27\u0e1a\u0e04\u0e38\u0e21 \u0e41\u0e25\u0e30\u0e2b\u0e25\u0e31\u0e01\u0e10\u0e32\u0e19\u0e27\u0e07\u0e08\u0e23\u0e02\u0e2d\u0e07\u0e21\u0e2d\u0e40\u0e15\u0e2d\u0e23\u0e4c.<\/p>","protected":false},"author":6,"featured_media":2735,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[95],"tags":[],"class_list":["post-3209","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pump"],"_links":{"self":[{"href":"https:\/\/borrapumps.com\/th\/wp-json\/wp\/v2\/posts\/3209","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/borrapumps.com\/th\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/borrapumps.com\/th\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/borrapumps.com\/th\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/borrapumps.com\/th\/wp-json\/wp\/v2\/comments?post=3209"}],"version-history":[{"count":1,"href":"https:\/\/borrapumps.com\/th\/wp-json\/wp\/v2\/posts\/3209\/revisions"}],"predecessor-version":[{"id":3219,"href":"https:\/\/borrapumps.com\/th\/wp-json\/wp\/v2\/posts\/3209\/revisions\/3219"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/borrapumps.com\/th\/wp-json\/wp\/v2\/media\/2735"}],"wp:attachment":[{"href":"https:\/\/borrapumps.com\/th\/wp-json\/wp\/v2\/media?parent=3209"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/borrapumps.com\/th\/wp-json\/wp\/v2\/categories?post=3209"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/borrapumps.com\/th\/wp-json\/wp\/v2\/tags?post=3209"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}