{"id":1756,"date":"2026-09-25T16:11:00","date_gmt":"2026-09-25T08:11:00","guid":{"rendered":"https:\/\/borrapumps.com\/blog\/vertical-multistage-pump-efficiency\/"},"modified":"2026-10-17T11:15:44","modified_gmt":"2026-10-17T03:15:44","slug":"hieu-suat-cua-may-bom-da-tang-doc","status":"publish","type":"post","link":"https:\/\/borrapumps.com\/vi\/blog\/vertical-multistage-pump-efficiency\/","title":{"rendered":"Hi\u1ec7u su\u1ea5t c\u1ee7a m\u00e1y b\u01a1m \u0111a t\u1ea7ng theo chi\u1ec1u d\u1ecdc: Nh\u1eefng y\u1ebfu t\u1ed1 n\u00e0o \u1ea3nh h\u01b0\u1edfng \u0111\u1ebfn m\u1ee9c ti\u00eau th\u1ee5 n\u0103ng l\u01b0\u1ee3ng"},"content":{"rendered":"<p>Vertical multistage pump efficiency is determined by the operating point of the complete system, not by the pump nameplate alone. A pump can have an attractive peak efficiency on its curve yet consume unnecessary energy when it is oversized, throttled, operated far from its best efficiency point, or connected to a high-loss pipe network. To reduce energy use, measure actual flow, suction and discharge pressure, motor input, and run hours; compare those values with the pump curve and the building&#8217;s demand profile. Then address avoidable head loss, staging, speed control, wear, and maintenance. Do not assume that replacing a motor or adding a drive will solve a hydraulic mismatch.<\/p>\n<h2>Separate pump efficiency from system efficiency<\/h2>\n<p>Pump hydraulic efficiency describes how much shaft power becomes useful water power at a specific flow and head. Motor efficiency describes conversion from electrical input to shaft power. Drive, coupling, and control losses may also matter. System efficiency considers whether the water is delivered at the flow and pressure actually needed. A highly efficient pump can be part of a wasteful system if a throttling valve discards excess pressure or water continuously bypasses back to a tank.<\/p>\n<p>The US Department of Energy&#8217;s <a href=\"https:\/\/www.energy.gov\/sites\/prod\/files\/2014\/05\/f16\/pump.pdf\" rel=\"noopener\" target=\"_blank\">pumping-system sourcebook<\/a> emphasizes the installed system curve and the pump&#8217;s best efficiency point. The DOE <a href=\"https:\/\/www.energy.gov\/cmei\/ito\/pump-systems\" rel=\"noopener\" target=\"_blank\">pump-systems resource page<\/a> lists actions such as reducing pipe and valve losses, correcting oversized pumps, and restoring internal clearances. These principles apply to vertical multistage pumps, but the actual savings must be calculated from the selected model and duty cycle.<\/p>\n<p>The <a href=\"https:\/\/borrapumps.com\/product\/cdlf-vertical-multistage-jockey-pump\/\">BorraPumps CDL(F) vertical multistage product<\/a> is a product reference for this discussion, within the broader <a href=\"https:\/\/borrapumps.com\/water-supply-booster-pump\/\">water-supply booster range<\/a>. Its visible stainless pump body and top-mounted motor do not establish a particular efficiency, stage count, material grade, or allowable speed. Obtain the current manufacturer curve and motor data for the exact configuration under consideration.<\/p>\n<h2>Find the real operating point<\/h2>\n<p>Measure flow, suction pressure, discharge pressure, and electrical input under representative low, normal, and peak demand. Calculate the pump differential head after accounting for gauge elevation and velocity differences if material. Plot the point on the selected pump curve. A pump that spends most hours far to the left of its best efficiency point may be too large for normal demand, even if it meets the design maximum. A pump operating far right may lack head and draw excessive current or enter an unsuitable region.<\/p>\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/borrapumps.com\/product\/cdlf-vertical-multistage-jockey-pump\/\"><img decoding=\"async\" src=\"https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-002.webp\" alt=\"BorraPumps CDL(F) Vertical Multistage Jockey Pump \u2014 illustrative setting\" class=\"wp-image-2735\" width=\"1536\" height=\"1024\" loading=\"lazy\" style=\"max-width:100%;height:auto;object-fit:contain\" srcset=\"https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-002.webp 1536w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-002-300x200.webp 300w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-002-1024x683.webp 1024w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-002-768x512.webp 768w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-002-18x12.webp 18w, https:\/\/borrapumps.com\/wp-content\/uploads\/2026\/10\/borra-realistic-20261016-img-002-600x400.webp 600w\" sizes=\"auto, (max-width: 1536px) 100vw, 1536px\" \/><\/a><figcaption>BorraPumps CDL(F) Vertical Multistage Jockey Pump. Illustrative setting based on the original BorraPumps product.<\/figcaption><\/figure>\n<p>Do not estimate flow from pressure alone. A changing control valve, parallel pump, or inlet condition can move the operating point. Use a calibrated meter where possible or a defensible temporary flow measurement. Record which pumps are running and whether a bypass or pressure-reducing valve is open. The <a href=\"https:\/\/borrapumps.com\/blog\/vertical-multistage-pump-selection\/\">vertical multistage pump selection guide<\/a> can help connect the duty point to a candidate pump, while this article focuses on energy after the duty is known.<\/p>\n<h2>Understand best efficiency point and operating range<\/h2>\n<p>The best efficiency point, or BEP, is the flow at which the pump&#8217;s hydraulic efficiency reaches its maximum for a given speed and impeller. The Hydraulic Institute&#8217;s <a href=\"https:\/\/datatool.pumps.org\/pump-fundamentals\/combined.html\" rel=\"noopener\" target=\"_blank\">pump-system operating-point tutorial<\/a> explains how the pump and system curves intersect and why that point should be checked near the efficient operating region. BEP is not automatically the one point the system must occupy at every moment, but it is a useful reference. The manufacturer may specify a preferred operating region and minimum continuous flow. Those limits protect reliability as well as efficiency. Running near shutoff can cause recirculation, heat, noise, and seal stress; running too far right may increase cavitation or motor load.<\/p>\n<p>A multistage pump adds head across successive stages. More stages can serve a high-head duty, but stage count alone does not predict efficiency. Impeller diameter, diffuser design, specific speed, speed, clearance, fluid properties, and the selected point all matter. When comparing two models, request efficiency curves at the same flow and required head. A smaller model near its efficient region may outperform a larger unit that spends most hours throttled.<\/p>\n<h2>Quantify avoidable head loss<\/h2>\n<p>Every unnecessary pressure drop adds work. Check pipe diameter, long runs, sharp fittings, strainers, partially closed isolation valves, check valves, and pressure-reducing devices. Measure pressure before and after suspect components at representative flow. A clean strainer may have a modest loss while a clogged one can consume substantial head; do not replace a pump before checking it. Increasing pipe size or reducing fittings can sometimes lower required pump head, though construction cost and velocity limits must be considered.<\/p>\n<p>The <a href=\"https:\/\/borrapumps.com\/blog\/booster-pump-head-calculation\/\">booster head-calculation article<\/a> shows how static elevation and flow-dependent friction combine. Static head does not disappear when speed falls, so affinity-law estimates alone can overstate energy savings in a high-static-head system. Recalculate the operating point where the reduced-speed pump curve meets the actual system curve. The DOE sourcebook discusses this distinction when evaluating variable-speed pumping.<\/p>\n<div style=\"overflow-x:auto;max-width:100%\">\n<table style=\"border-collapse:collapse;width:100%;min-width:560px\">\n<thead>\n<tr>\n<th>Observation<\/th>\n<th>Likely energy effect<\/th>\n<th>Measurement to make<\/th>\n<th>Potential action<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Discharge valve routinely throttled<\/td>\n<td>Pump creates head that is deliberately lost<\/td>\n<td>Pressure across valve at normal flow<\/td>\n<td>Revisit pump size or control strategy<\/td>\n<\/tr>\n<tr>\n<td>Bypass open for long periods<\/td>\n<td>Water is pumped without useful delivery<\/td>\n<td>Bypass flow and run hours<\/td>\n<td>Correct minimum-flow and staging design<\/td>\n<\/tr>\n<tr>\n<td>Strainer pressure loss rising<\/td>\n<td>Extra head is required for same delivery<\/td>\n<td>Differential pressure at comparable flow<\/td>\n<td>Clean or repair strainer<\/td>\n<\/tr>\n<tr>\n<td>Several pumps run at light load<\/td>\n<td>Each may be far from efficient region<\/td>\n<td>Flow and input per operating pump<\/td>\n<td>Review staging and trim-pump option<\/td>\n<\/tr>\n<tr>\n<td>High motor current with low useful flow<\/td>\n<td>Possible hydraulic or mechanical mismatch<\/td>\n<td>Current, flow, head, speed, vibration<\/td>\n<td>Inspect operating point and condition<\/td>\n<\/tr>\n<tr>\n<td>Wear reduces delivered head<\/td>\n<td>More run time or speed may be needed<\/td>\n<td>Trend curve against baseline<\/td>\n<td>Inspect clearances and components<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>The table is diagnostic rather than a claim of fixed savings. Record measurements before and after a change under comparable demand. A pump that appears less efficient may simply be serving a different head or flow.<\/p>\n<h2>Choose staging and speed control carefully<\/h2>\n<p>If demand varies widely, several smaller pumps or a variable-speed arrangement can help keep the operating point closer to useful duty. Staging must be based on combined curves and the demand distribution. A second pump should start when the first can no longer meet the pressure target at the required flow, not merely after a fixed elapsed time. The <a href=\"https:\/\/borrapumps.com\/blog\/two-pump-vs-three-pump-booster-set\/\">two-pump versus three-pump guide<\/a> explains how staging steps and redundancy differ.<\/p>\n<p>A variable-frequency drive changes pump speed and can reduce wasted head in some systems. It does not guarantee savings: at very low flow the motor, drive, and pump may work poorly, and a high static lift may limit the reduction in speed. Confirm minimum flow, motor cooling, maximum speed, and stable sensor feedback. The <a href=\"https:\/\/borrapumps.com\/blog\/booster-pump-vfd-selection\/\">booster VFD selection guide<\/a> covers electrical and control inputs. Compare whole-system input at several operating points before choosing a drive solely from an affinity-law estimate.<\/p>\n<h2>Watch motor and drive losses<\/h2>\n<p>Read the exact motor nameplate and efficiency information. A premium-efficiency motor may help when the pump runs many hours, but its benefit is limited if the hydraulic system wastes much more energy through excess head. A drive adds its own losses and may change motor heating. Evaluate the combined wire-to-water performance at the expected load points, not only peak motor efficiency. Where multiple motors are available, compare their actual operating hours and duty.<\/p>\n<p>Electrical current alone is not a complete energy measurement. Record voltage, current, power factor, real power, speed, and run time using appropriate instruments and qualified personnel. An unexpectedly low current can accompany low flow, a dry-running condition, or a different operating point; it is not automatically evidence of efficiency. Never open a live panel to collect data without the site&#8217;s electrical safety procedure.<\/p>\n<h2>Account for wear and water conditions<\/h2>\n<p>Erosion, corrosion, fouling, and excessive clearances can reduce hydraulic performance. Seal leakage may also indicate operation outside a suitable range, though a seal can fail for other reasons. Trend flow, head, vibration, temperature, and input against a commissioning baseline. If duty has changed, a worn pump and a poorly selected pump can look similar until the curve and condition are examined. The <a href=\"https:\/\/borrapumps.com\/blog\/vertical-multistage-pump-sizing-guide\/\">vertical multistage sizing guide<\/a> helps distinguish an incorrect duty selection from deterioration of an otherwise suitable pump.<\/p>\n<p>Check fluid temperature, density, viscosity, and solids against the pump&#8217;s documented limits. A water-pump efficiency curve may not represent a different fluid accurately. The condition of valves and pipework can also evolve: a valve left partly closed after maintenance changes the system curve without changing the pump itself. Confirm correct rotation, venting, and inlet condition after service.<\/p>\n<h2>Build a simple energy assessment<\/h2>\n<p>Collect a representative duty profile rather than one spot reading. For each operating band, record flow, total differential head, real input power, number of pumps, speed or stage, and annual hours. Energy for that band is input power multiplied by hours. Add the bands and compare alternative configurations on the same delivered flow and pressure. Include maintenance, controls, and standby needs in a lifecycle comparison.<\/p>\n<p>If measurements are limited, label estimates clearly and test the most influential assumptions. Avoid inventing a percentage saving before the system curve, pump curve, and hours are known. A useful first intervention may be cleaning a strainer, correcting a control setpoint, or changing a staging threshold. Re-measure after the intervention and retain both records so the claimed improvement can be verified.<\/p>\n<h2>Questions to send a supplier<\/h2>\n<p>Request the exact pump and motor curves, efficiency across the proposed operating range, minimum continuous flow, speed limits, inlet-pressure requirements, permissible fluid conditions, and staged operation with any parallel pumps. Give the supplier normal and peak flow, required head, inlet pressure range, pipe-loss estimates, run-hour profile, electrical supply, and control objective. Ask how the proposed selection performs at normal duty, not only design peak. The correct choice is the one that meets service reliably with reasonable whole-system energy over the actual duty cycle.<\/p>\n<h2>Frequently asked questions<\/h2>\n<h3>Is a vertical multistage pump always more efficient than a single-stage pump?<\/h3>\n<p>No. Efficiency depends on the duty point and the specific models. A multistage design may be appropriate for higher head, but compare curves at the same required flow and head.<\/p>\n<h3>Will a VFD always reduce electricity use?<\/h3>\n<p>No. Savings depend on the system curve, static head, demand variation, speed range, and drive and motor losses. Measure or model the duty cycle.<\/p>\n<h3>Can I judge efficiency from motor current?<\/h3>\n<p>No. Current alone omits voltage, power factor, delivered flow, and head. Use real input power and hydraulic measurements.<\/p>\n<h3>What should be checked before replacing an inefficient pump?<\/h3>\n<p>Verify flow and head, valve positions, strainer loss, bypass flow, controls, motor input, rotation, wear, and the selected pump curve.<\/p>\n<h2>Further learning<\/h2>\n<p>The NPTEL IIT Kharagpur <a href=\"https:\/\/www.youtube.com\/watch?v=p54HAatQOcA\" rel=\"noopener\" target=\"_blank\">centrifugal-pump characteristics lecture<\/a> explains pump curves and operating points, which underpin the efficiency checks above. Use the exact manufacturer curve for procurement and commissioning.<\/p>\n<div style=\"position:relative;padding-bottom:56.25%;height:0;overflow:hidden\"><iframe allowfullscreen=\"\" loading=\"lazy\" src=\"https:\/\/www.youtube-nocookie.com\/embed\/p54HAatQOcA\" style=\"position:absolute;top:0;left:0;width:100%;height:100%;border:0\" title=\"NPTEL IIT Kharagpur: Characteristics of a Centrifugal Pump\"><\/iframe><\/div>\n<p><script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Is a vertical multistage pump always more efficient than a single-stage pump?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. Efficiency depends on the duty point and the specific models. A multistage design may be appropriate for higher head, but compare curves at the same required flow and head.\"}},{\"@type\":\"Question\",\"name\":\"Will a VFD always reduce electricity use?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. Savings depend on the system curve, static head, demand variation, speed range, and drive and motor losses. Measure or model the duty cycle.\"}},{\"@type\":\"Question\",\"name\":\"Can I judge efficiency from motor current?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. Current alone omits voltage, power factor, delivered flow, and head. Use real input power and hydraulic measurements.\"}},{\"@type\":\"Question\",\"name\":\"What should be checked before replacing an inefficient pump?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Verify flow and head, valve positions, strainer loss, bypass flow, controls, motor input, rotation, wear, and the selected pump curve.\"}}]}<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>T\u00ecm hi\u1ec3u nh\u1eefng y\u1ebfu t\u1ed1 \u1ea3nh h\u01b0\u1edfng \u0111\u1ebfn hi\u1ec7u su\u1ea5t c\u1ee7a m\u00e1y b\u01a1m \u0111a t\u1ea7ng d\u1ecdc, bao g\u1ed3m \u0111i\u1ec3m v\u1eadn h\u00e0nh, t\u1ed5n th\u1ea5t \u0111\u01b0\u1eddng \u1ed1ng, giai \u0111o\u1ea1n h\u00f3a, \u0111i\u1ec1u khi\u1ec3n t\u1ed1c \u0111\u1ed9, hao m\u00f2n v\u00e0 m\u1ee9c ti\u00eau th\u1ee5 n\u0103ng l\u01b0\u1ee3ng \u0111\u01b0\u1ee3c \u0111o l\u01b0\u1eddng.<\/p>","protected":false},"author":6,"featured_media":2915,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[95],"tags":[],"class_list":["post-1756","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pump"],"_links":{"self":[{"href":"https:\/\/borrapumps.com\/vi\/wp-json\/wp\/v2\/posts\/1756","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/borrapumps.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/borrapumps.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/borrapumps.com\/vi\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/borrapumps.com\/vi\/wp-json\/wp\/v2\/comments?post=1756"}],"version-history":[{"count":5,"href":"https:\/\/borrapumps.com\/vi\/wp-json\/wp\/v2\/posts\/1756\/revisions"}],"predecessor-version":[{"id":2793,"href":"https:\/\/borrapumps.com\/vi\/wp-json\/wp\/v2\/posts\/1756\/revisions\/2793"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/borrapumps.com\/vi\/wp-json\/wp\/v2\/media\/2915"}],"wp:attachment":[{"href":"https:\/\/borrapumps.com\/vi\/wp-json\/wp\/v2\/media?parent=1756"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/borrapumps.com\/vi\/wp-json\/wp\/v2\/categories?post=1756"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/borrapumps.com\/vi\/wp-json\/wp\/v2\/tags?post=1756"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}